Call Us: 800-218-4947

SIT

     Checkout

Free Delivery $500 Orders
Free Curb Side $500 Orders
*Some Exceptions Apply

MAJ20010811 | Valve Replacement Kit | Honeywell to SIT | Gas Fireplaces | Ng

Honeywell to SIT conversion
Honeywell to SIT conversionSIT Connection Diagram

SKU:20010811
Inventory ID:03610822
Select Item:
Quantity:

Gas Valves DO NOT have return privileges.

LP SKU is 20010680

Convert Honeywell Gas Valve to SIT Valve on Vented Gas Burning Fireplaces

Kit RP275 for natural gas and Kit RP269 for Liquid propane is approved for Majestic, Vermont Casting, Monessen and HHT fireplaces.

Honeywell millivolt gas valve is no longer manufactured. This kit can be used convert from the discontinued Honeywell system to SIT millivolt valve system. Some field modification may need to be necessary w/ bracket and gas connections. 

Kit Includes:

  • Gas Valve
  • Spark Ignitor
  • Valve Bracket
  • Ignitor Bracket
  • Bracket Fasteners

 

This conversion might also be used on Superior, Lennox & other Direct Vent brands that have the Honeywell millivolt gas valve. 

Rating: 4.0 / 5 ( out of 2 reviews )
My Majestic DV360 fireplace had a defective NLA Honeywell valve. This kit made it all better. You will be notching out the supplied bracket to fit under a metal lip. I also had to elongate the three small mounting holes on top of the bracket to allow some side-to-side adjustment. YOU MUST VERIFY THE DIRECTION OF GAS FLOW ON THE NEW VALVE. IT'S PHYSICAL APPEARANCE IS REVERSE OF THE HONEYWELL YOU ARE REPLACING!
-   5 years ago -
I bought 1 of these valves along with a new pilot and remote and it was money well spent. My stove works great and I think it throws more heat if you have an old Honeywell valve that doesn't work anymore don't waste your money on a new stove just buy this kit.
-   5 years ago -